Skip to content
Al-Shaker for Scientific and Medical Supplies

EASYCAL G2

Automatic calibration station for Lifeloc testers: cal under 2 minutes, cal-check under 30 seconds, 34/60/105/116 L cylinders, 0.040/0.080/0.100 gas, ~10,000 records.

Key specifications

Calibration time
<2 min
Cal-check time
<30 s
Cylinder sizes
34 / 60 / 105 / 116 L
Gas standards
0.040 / 0.080 / 0.100 BAC
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The EASYCAL G2 automatic calibration station automates calibration, cal-checks, record keeping, and gas management for Lifeloc breath alcohol testers. Cradle the instrument, power on, and the station runs the sequence. Calibration is under 2 minutes; a cal-check is under 30 seconds. The housing takes 34 L, 60 L, 105 L, and 116 L dry-gas cylinders. Published gas standards are 0.040, 0.080, and 0.100 BAC (other common standards on request). Memory holds about 10,000 records before overwrite. The station is approximately 10.6 × 9.25 × 5.3 in (270 × 235 × 135 mm) and 3 lb. A color resistive touchscreen, Bluetooth printer link, USB software updates, seat and cylinder-pressure sensors, and automatic altitude correction are on the published specification. Power is 9 VDC 3 A regulated or six C alkaline cells with auto sleep. Operating range is 50–113 °F (10–45 °C).

Lifeloc lists EASYCAL G2 as compatible with currently manufactured Lifeloc EBTs and PBTs. A Lifeloc Operator and Calibration Technician Certification (C-LOCT) is required to calibrate a Lifeloc evidential breath tester, regardless of method.

Al-Shaker specifies EASYCAL G2 with the Phoenix 6.0BT or other Lifeloc testers on the same account, the first cylinder size and gas standard, and the print log, then installs, trains, and supports the station across Jordan, the GCC, and MENA.

Specifications

Technical specifications

7 parameters

Performance

Calibration time
<2 min
Cal-check time
<30 s

Gas

Cylinder sizes
34 / 60 / 105 / 116 L
Gas standards
0.040 / 0.080 / 0.100 BAC

Memory

Records
~10,000 before overwrite

Installation

Dimensions (L × W × H)
10.6 × 9.25 × 5.3 in
Weight
3 lb
Features

Key features

  • 01

    Cal under 2 minutes

    Published calibration under 2 minutes and cal-check under 30 seconds after the tester is seated.

  • 02

    34 to 116 L dry gas

    Accepts 34, 60, 105, and 116 L cylinders at 0.040, 0.080, and 0.100 BAC standards.

  • 03

    ~10,000 records

    Stores serial, date, pass/fail, gas lot, expiry, and optional operator and location before overwrite.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.