Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: CFG-14D, CFG-12D

Microhematocrit Centrifuge CFG-14D, CFG-12D

Compact microhematocrit centrifuges spinning 24 capillary tubes at up to 12000 rpm and 13680 ×g, driven by maintenance-free brushless DC motors.

Key specifications

Speed Range
CFG-14D: 200-12000rpm, increment: 10rpm; CFG-12D: 500-12000rpm, increment: 100rpm
Max. RCF
13680×g
Speed Accuracy
CFG-14D: ±20; CFG-12D: ±100
Run Time
CFG-14D: 30sec-99min/Continuous; CFG-12D: 10sec-99min/Continuous
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The CFG-14D and CFG-12D are microhematocrit centrifuges for spinning capillary tubes, with a rotor holding 24 capillaries. Both reach 12000 rpm and a maximum RCF of 13680 ×g using maintenance-free brushless DC motors and LCD displays.

The CFG-14D covers 200 to 12000 rpm in 10 rpm steps with ±20 rpm accuracy and run times from 30 seconds to 99 minutes or continuous. It adds speed/RCF switching, a short-time pulse run, an audible alert, overspeed and over-temperature detection, automatic internal diagnosis and automatic rotor identification, with 30-second acceleration and braking.

The CFG-12D is the simpler model, covering 500 to 12000 rpm in 100 rpm steps with run times from 10 seconds to 99 minutes or continuous and a door interlock. Both units are compact at 280 × 364 mm, weighing 10.5 kg and 8.5 kg.

Specifications

Technical specifications

12 parameters

Door interlock

Speed Range
CFG-14D: 200-12000rpm, increment: 10rpm; CFG-12D: 500-12000rpm, increment: 100rpm
Max. RCF
13680×g
Speed Accuracy
CFG-14D: ±20; CFG-12D: ±100
Run Time
CFG-14D: 30sec-99min/Continuous; CFG-12D: 10sec-99min/Continuous
Motor
Brushless DC motor
Display
LCD
Safety Devices
CFG-14D: Door interlock, Overspeed detector; Automatic internal diagnosis, Automatic rotor identification; CFG-12D: Door interlock
Acceleration/Braking time
CFG-14D: 30s↑30s↓; CFG-12D: 40s↑40s↓
Power
CFG-14D: Single-phase, 200V-240V,50Hz/60Hz, 5A; 100V-120V,50Hz/60Hz, 5A 160W; CFG-12D: Single-phase, 200V-240V,50Hz/60Hz, 5A; 380W
Dimension[W×D×H]
CFG-14D: 280mm×364mm×274mm; CFG-12D: 280mm×364mm×213mm
Weight
CFG-14D: 10.5kg; CFG-12D: 8.5kg
Advanced features
Speed/RCF switch; Short-time run function; sound-alert function
Features

Key features

  • 01

    24 capillary capacity

    Rotor for 24 capillary tubes at up to 12000 rpm and 13680 ×g.

  • 02

    Two models

    CFG-14D with advanced control and safety, CFG-12D for straightforward routine use.

  • 03

    Fine speed control

    CFG-14D adjusts from 200 rpm in 10 rpm increments with ±20 rpm accuracy.

  • 04

    Pulse operation

    Short-time run function for quick spins on the CFG-14D.

  • 05

    Safety features

    Door interlock on both models, plus overspeed and over-temperature detection on the CFG-14D.

  • 06

    Brushless motor

    Maintenance-free brushless DC motor with LCD display.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.